The parameter used in the above configuration is explained below.

ParameterDescriptionTuning Recommendation
StatWorkerIdleInterval
The number of milliseconds that should elapse after a batch of statistical data is processed (to be published in the Analytics Dashboard) before sending another batch.

The general recommendation is 5000 milliseconds (i.e. 5 seconds). Therefore, your ESB is tuned to this value by default.

When the ESB is handling a high load of requests, this value can be reduced to increase the frequency with which the resulting statistics are published in the Analytics Dashboard. This helps to avoid storing too much data in the ESB server causing an overconsumption of memory.

When the load of requests handled by the ESB is comparatively low, this time interval can be increased to reduce the system overhead incurred by frequent processing.